CONDITIONS
WAVEFORM
VOLTAGE OUTPUT
LINE REGULATION
LOAD REGULATION
DISTORTION
FREQUENCY
MINIMUM
-
-5%
-
-
-
-0.1%
TYPICAL
SINUSOIDAL
NOMINAL
0.1%
0.5%
1.5%
NOMINAL
MAXIMUM
-
+5%
0.5%
1%
2%
+0.1%
GENERAL
Case size (HxWxD)
125W case size= 2.16" X 4.93" X 7.90"
(2 lbs)
250W case size= 2.77" X 5.23" X 10.768”
(5 lbs)
600W case size= 3.57" X 7.69" X 12.10"
(6.5 lbs)
1100W case size= 3.57" X 7.69" X 15.05"
(10 lbs)
2000W case size= 4” X 9” X 18”
(15 lbs)
MECHANICAL
ENVIRONMENTAL
Temperature: -25 to 30 C full power
derated 20% per 10 C,
Humidity: 5 to 95% non condensing
Altitude: -200 to 10k feet full power,
derated above 10k
Audible Noise: Less than 45dbA
Cooling: 600W/1100W Thermo-
statically controlled
forced air. 125W/250W
convection cooled.
Finish: Painted aluminum
Warranty: Full year parts labor
above 30 C.
*Over Voltage: Shut off at maximum input
voltage, per input conditions.
Automatic reset upon fault
correction.
*Under Voltage: Shut off at minimum input
voltage, per input conditions
*Thermal: 105 C internal temperature.
Warning buzz 5 C before
shut off
Output Short: Unit shuts off (manual reset)
*Automatically reset
PROTECTION
CIRCUITRY
XP SERIES POWER INVERTER SPECIFICATIONS
XP Options:
- conformal coating (07 option)
- low idle current drain (02 option)*
- circuit board with heat sink only
(04 option) many other options
available for OEM applications,
consult factory.
OPTIONS
*1100 watt only
See www.exeltech.com for more data regarding XP Series inverters.
*10W with X2 option , **remote switchable
OUTPUT POWER
CONTINUOUS
POWER
SURGE
POWER
NO LOAD
POWER
OUTPUT
VOLTAGE
OUTPUT
CURRENT
WEIGHT
LBS.
1100W 117 +/-6% 5.1 6.5
1100W 230 +/-6% 2.7 6.5
1100W**
1100W**
1100W**
600W**
250W**
250W**
250W**
125W
125W
600W**
600W**
8W
9W
6.51100W
8W
100 +/-6% 6.0
2200W
2200W
2200W
20W*
20W*
20W* 100 +/-6%
117 +/-6%
230 +/-6% 10
10
10
9.5
11.0
4.8
150W
150W
5W
5W
100 +/-6%
117 +/-6% 2
2
1.1
1.2
300W
300W
300W 6W
6W
7W
100 +/-6%
117 +/-6%
230 +/-6%
2.5
2.1
1.1
5
5
5
4000W
100 +/-2%
12W
20.0
15
2000W
2000W
2000W
120 +/-2%
15
15
4000W
4000W
12W
12W
16.7
8.7
230 +/-2%
Page 15
INPUT POWER
*Indicates typical cut-off voltage/warning buzzer voltage
+/- 3%
1
TYPICAL
EFFICIENCY
@ FULL
POWER
PEAK
EFFICIENCY
@ 1/3
POWER
85% 87%
87% 89%
88% 90%
87% 89%
88% 90%
87% 90%
SEE CURVES
SEE CURVES
SEE CURVES
SEE CURVES
SEE CURVES
SEE CURVES
SEE CURVES
SEE CURVES
MAXIMUM
(TYPICAL)
16.5V
33V
44V
62V
91V
149V
1
15V
30V
60V
80V
SYSTEM
(TYPICAL)
13.8V
27.6V
36.8V
55.2V
75.9V
125V
13.8V
27.6V
55.2V
75.9V
MINIMUM
(TYPICAL)
10.4/10.6*
19/21V*
26.5/28V*
41.5/42.5V
57.5/58.5V*
94/95V*
1
10.5/10.8V
21/21.6V
42/43.2V
56/57.6V
MODEL
VOLTAGE
125/250/600/1100 12V
125/250/ 24V600/1100
125/250/ 32V600/1100
125/250/ 48V600/1100
125/250/ 66V600/1100
125/250/ 108V600/1100
2000 12V
2000 24V
2000 48V
2000 66V
Kommentare zu diesen Handbüchern